Let’s start with I got a good grasp on things but also a bit green lol best I can do at 25
Just looked at a walk in freezer 8x9x8 outdoor with entry and wall shared with walk in cooler. Struggles to come below 10 degrees during summer. Indoor unit looks original heat craft elc096 can’t find much but I think it’s 9600btu. Txv is rated for 1/2-1 ton. Compressor has been replaced with a cf06k6e unsure if original. But according to specs it’s at best rated for 6700 btu for -10. I think the evap is sized correctly but the compressor/condenser is not sized enough and I think the box roughly needs 7k btu minimum for the box
Edit: aw fuck almost forgot 404a
Specs at time of arrival Indoor temp 10-15 Outdoor temp 80-83 High 240 Low 32 Sub 3 glass is clear Super at evap 15
Can’t get super any lower than 15 at the evap. But my suction is not right either and wonder if it’s all because compressor cannot take the load. Or should I look at something else.
Or I might be missing something. Defrost is not on lol.