Thursday, June 16, 2022

Replacing Dixell Controller in Atosa

I have a 2 year old Atosa fridge that i had to unplug for 2 months. When i fired it up the controller setting was showing some wild temps fluctuating from -12F to 44F

Internal temp of the cooler shows 40 and it goes through its cooling cycles fine. No frost or icing and condenser was cleaned before plugging back in. It was pretty clean to start with.

I called tech service at Atosa and they recommended switching out the control with part number W0302186

Looking online I see a ton of options for dixell controllers Some being much cheaper than others. Are the cheaper ones the same with no programming? Do I need to get the OEM Atosa one?

submitted by /u/Pizzahead510
[link] [comments]